Feature is NOT enabled and will be skipped over when navigating through features with MODE button.
GREEN FUEL OPEN LOOP
Feature allows fuel adjustment when the Green zone is active which is typically during idle and very light cruising conditions. Feature is an open loop fueling mode meaning an AFR of 13 is 0% change. To the left adds fuel and to the right subtracts fuel from the stock ECU map.
YELLOW FUEL OPEN LOOP
Feature allows fuel adjustment when the Yellow zone is active which is typically during cruising conditions. Feature is an open loop fueling mode meaning an AFR of 13 is 0% change. To the left adds fuel and to the right subtracts fuel from the stock ECU map.
YELLOW FUEL CLOSED LOOP
Feature allows fuel adjustment when the Yellow zone is active which is typically during cruising conditions. Feature is a closed loop fueling mode meaning the system is trying to target the set AFR value.
RED FUEL OPEN LOOP
Feature allows fuel adjustment when the Red zone is active which is typically during full throttle conditions. Feature is an open loop fueling mode meaning an AFR of 13 is 0% change. To the left adds fuel and to the right subtracts fuel from the stock ECU map.
RED FUEL CLOSED LOOP
Feature allows fuel adjustment when the Red zone is active which is typically during full throttle conditions. Feature is a closed loop fueling mode meaning the system is trying to target the set AFR value.
YELLOW LWR SW PT
Feature allows adjustment of when the Yellow zone engages. Needs to be set so the Yellow zone is on during all cruising conditions.
RED LWR SW PT
Feature allows adjustment of when the Red zone engages. Needs to be set so the Red zone is on during all full throttle conditions.
ACCEL PUMP FUEL
Feature allows fuel adjustment when the Accel Pump is active. Feature targets quick movements of the throttle and adjusts fuel based on the rate of change. Feature is an open loop fueling mode meaning an AFR of 13 is 0% change. To the left adds fuel and to the right subtracts fuel from the stock ECU map.
CLOSED LOOP SWITCH PT
Trim code feature which determines the transition point to allow the hard set auto-tune values to run in closed loop. Setting of 10.5 or +25 will engage closed loop. Setting of 15.5 or -25 will turn-off closed loop and adjust fuel based on the open loop adjustments.